- Print
- DarkLight
- PDF
Advanced Configuration Guide
Advanced Configuration Guide Document
Setting Configuration Settings via WTDataCollector
All configuration settings may be set programmatically using the method [WTDataCollector setValue:forConfigKey:persists:]. All settings are stored as strings. Each configuration key is associated with a constant for easier reference.
See Configuration Settings below for details.
For example, to set the maximum number of persisted events config setting, use the following line of code:
Swift
WTDataCollector.kWTConfigMaxPersistedEvents.sharedCollector().setValue("10000", forConfigKey:kWTConfigMaxPersistedEvents,
persists:true)
Objective-C
[[WTDataCollector sharedCollector] setValue:@"10000" forConfigKey:kWTConfigMaxPersistedEvents
persists:YES];
If the persists flag is set to YES, the configuration setting will be written to disk and persisted across application stops and starts. If it is set to NO, the setting will only be set in memory and will reset to the value stored in webtrends.plist or its default value.
Setting Configuration Settings via webtrends.plist
Configuration settings may also be set by editing the webtrends.plist file. Settings defined in the this file will have a lower priority than settings defined programmatically via the [WTDataCollector setValue:forConfigKey:persists:] method. If you choose to edit the webtrends.plist file directly, you must use the string literals as keys, not the
constant name.
Configuration Settings
The following settings are known to the Webtrends SDK. Changing the values associated with any of them will change the behavior of the SDK as explained under each setting’s “Description”.
App Delegate Class Name
Description: Sets the name of the AppDelegate class for your application. This is only required if you are changing the default from “AppDelegate” and you are using Automatic Events.
String Literal: wt_dc_app_delegate_class_name
Constant Name: kWTAppDelegateClassName
Default Value: “AppDelegate"
Acceptable Values: Any valid class name
Automatic Events Enabled
Description: Controls whether or not certain events will be logged automatically. See the Automatic Events Guide for details on what events are automatically collected.
String Literal: wt_dc_automatics_enabled
Constant Name: kWTConfigAutomaticsEnabled
Default Value: “false"
Acceptable Values: boolean as a string — "true” or “false”
Automatic Send Threshold Percent
Description: Percentage of the event store capacity (defined in the Max Persisted Events configuration setting) at which events will be automatically sent to the Webtrends data collection servers. This setting expects an integer from 0 to 100, inclusive.
String Literal: wt_dc_auto_send_threshold_percent
Constant Name: kWTConfigAutoSendThresholdPercent
Default Value: “80"
Acceptable Values: integer as a string — (an integer from "0” to “100”, inclusive)
Battery Minimum Charge Percentage
Description: Controls at what battery level to stop Webtrends event transmission. When the battery level falls below this level, event transmission to the Webtrends data collection servers is disabled. After iOS reports that battery power is restored to a level above this threshold, event transmission will resume. Since iOS reports battery levels to the SDK in increments of 5%, actual battery level may not trigger event transmission to resume
immediately, depending on the value of this configuration setting.
String Literal: wt_dc_battery_min_charge_percent
Constant Name: kWTConfigBatteryMinimumChargePercentage
Default Value: “20"
Acceptable Values: integer as a string — an integer between "0” and “100”, inclusive
Collection URL Base
Description: The URL address of the Webtrends data collection server
String Literal: wt_dc_collection_url_base
Constant Name: kWTConfigCollectionUrlBase
Default Value: “https://scs.webtrends.com/v2/"
Acceptable Values: string — A valid URL string including the protocol (http:// or https://)
DCSID
Description: The Webtrends-assigned DCSID or Account GUID used for this account
String Literal: wt_dc_dcsid
Constant Name: kWTConfigDCSID
Default Value: none
Acceptable Values: Webtrends-supplied DCSID string
While not strictly required, your app must be configured with a valid DCSID for the data to be collected by your SDC.
Debug Logging Enabled
Description: Enables or disables debug logging for the SDK. When enabled, event transmission and SDK state information will be printed to the console.
String Literal: wt_dc_debug
Constant Name: kWTConfigDebug
Default Value: “true"
Acceptable Values: boolean as a string — "true” or “false”
Events Per Send
Description: Events are collected and sent in batches to the Webtrends data collection servers. This setting controls the number of events to send in a single batch.
String Literal: wt_dc_event_send_maximum
Constant Name: kWTConfigEventsPerSend
Default Value: “500"
Acceptable Values:
Needs to be reset to "1", OnPremises SDCs do not have the capacity for batch event processing.
Extra Parameters for All Events
Description: If set, these key/value pairs will be sent along with every event. Format the query parameters as valid JSON e.g.: {"foo":"bar","fee":"fum"}.
String Literal: wt_dc_extra_params
Constant Name: kWTConfigExtraParams
Default Value: empty string
Acceptable Values: comma separated key=value string formatted as JSON {“key1”:“value1”,“key2”:“value2”,…}
If you are upgrading an older implementation, this replaces wt_dc_collection_url_extra_query_params which has been deprecated. The only difference is the name, which reflects the way that extra parameters are now passed to the collection servers. The SDK now passes this data within the body of the event (as part of the payload), not in the query string.
If values are set in this setting and key/value pairs with the same keys (name collision) are passed in using the withCustomParams: parameter, the customParams will take precedence over values in this setting.
HTTP Connection Timeout Milliseconds
Description: Controls the maximum amount of time (in milliseconds) to pass before abandoning a Webtrends SDK-related HTTP request.
String Literal: wt_dc_http_connect_timeout_millis
Constant Name: kWTConfigHTTPConnectionTimeoutMilliseconds
Default Value: “10000"
Acceptable Values: integer as a string — (any valid positive integer value)
HTTP Read Timeout Milliseconds
Description: Controls the maximum amount of time to wait (in milliseconds) for a response from a Webtrends SDK-related HTTP connection.
String Literal: wt_dc_http_read_timeout_millis
Constant Name: kWTConfigHTTPReadTimeoutMilliseconds
Default Value: “30000"
Acceptable Values: integer as a string — (any valid positive integer value)
Max Events Per Request
Description: If the application is configured to use API version 2 (or higher), this setting controls how many events are bundled in a single HTTP request.
String Literal: wt_dc_max_events_per_request
Constant Name: kWTConfigMaxEventsPerRequest
Default Value: “250"
Acceptable Values: integer as a string — (any valid positive integer value)
Max Persisted Events
Description: The maximum number of events to store locally on the device. If new events are generated while the event store is full, the oldest events will be permanently deleted.
String Literal: wt_dc_event_table_size_maximum
Constant Name: kWTConfigMaxPersistedEvents
Default Value: “5000"
Acceptable Values: integer as a string — (any valid positive integer value)
Max Session Milliseconds
Description: Controls the maximum amount of time (in milliseconds) to wait before forcing a new session to start.
String Literal: wt_dc_max_session_millis
Constant Name: kWTConfigMaxSessionMilliseconds
Default Value: “28800000"
Acceptable Values: integer as a string — (any valid positive integer value)
Only Send Over Wifi
Description: Controls whether events are sent when wifi is unavailable.
String Literal: wt_dc_only_send_over_wifi
Constant Name: kWTConfigOnlySendOverWifi
Default Value: “false"
Acceptable Values: boolean as a string — "true” or “false”
Report Location Enabled
Description: When enabled (and CoreLocation services in the application are enabled), sends geo location coordinates with every event. The application must be configured with CoreLocation authorization. The SDK will not request authorization unilaterally. It will only use this information if it is already authorized in your application.
String Literal: wt_dc_report_location_enabled
Constant Name: kWTConfigReportLocationEnabled
Default Value: “false"
Acceptable Values: boolean as a string — "true” or “false”
Send Interval Milliseconds
Description: Time (in milliseconds) between stored events being transmitted to the Webtrends data collection servers. If no events are queued, nothing is transmitted and a new send event is scheduled.
String Literal: dc_send_interval_millis
Constant Name: kWTConfigSendIntervalMilliseconds
Default Value: “600000"
Acceptable Values: integer as a string — (any valid positive integer value)
Send Screen View Events with Automatic Activity View Events
Description: Enable/Disable sending a screen View event along with every automatic activity event. This only applies when automatic events are enabled. This may be enabled/disabled manually or by RCS.
String Literal: wt_dc_send_screen_view_with_activity_view_enabled
Constant Name: kWTConfigSendScreenViewWithActivityViewEnabled
Default Value: “false"
Acceptable Values: boolean as a string — "true” or “false”
Session Timeout Milliseconds
Description: Controls the maximum amount of time (in milliseconds) since the last event before forcing a new session to start.
String Literal: wt_dc_session_timeout_millis
Constant Name: kWTConfigSessionTimeoutMilliseconds
Default Value: “1800000"
Acceptable Values: integer as a string — (any valid positive integer value)
Timezone
Description: The timezone that will be used to calculate session information. This setting is only used to establish when a new day starts/ends. Generally, this should be set to the timezone that will be used for session reporting. It is NOT NECESSARILY the timezone that the device is operating in.
String Literal: wt_dc_timezone
Constant Name: kWTConfigTimezone
Default Value: “-8” (Pacific Time)
Acceptable Values: integer as a string — (between “-12” and “12”, inclusive)
Webtrends SDK Enabled
Description: Enable/Disable the Webtrends Data Collector SDK
String Literal: wt_dc_enabled
Constant Name: kWTConfigEnabled
Default Value: “true"
Acceptable Values: boolean as a string — "true” or “false"
If this config setting is set to ‘false’, then the SDK will no longer collect events, store events, or send events. Effectively, setting this to ‘false’ renders the entire SDK inoperable.