- Print
- DarkLight
- PDF
Historical Counts Parameter
Webtrends generates and maintains these parameters using the Webtrends analysis process when you enable Visitor History. For more information, see “Visitor History Parameters.”
WT.vr.vc
WT.vr.vc=VisitCount
Identifies the total number of visits recorded for a visitor. This is an integer representing the number of visits since the visitor’s first visit. When using this as a measure for the Visitor dimension, use the maximum value. When using this as a measure for dimensions other than Visitor, you usually configure the average value.
The sum of this measure has no meaning.
WT.vr.vcb
WT.vr.vcb=High/Moderate/Some/Low descriptor
Classifies the value of the WT.vr.vc
parameter into one of four categories.
This parameter is non-numeric and used as a dimension. You can change the number of categories by editing the vrbucket.ini
file. By default, the file is configured as follows:
[VCBValues]
High = 25
Moderate = 15
Some = 5
The following table shows the meaning of the default values:
[VCBValues] | Meaning |
---|---|
High=25 | 25 < x |
Moderate=15 | 15 > x < 25 |
Some=5 | 5> x < 15 |
By default, the minimum value for Some
is 5. Any visitor whose visit count value is less than 5 is assigned to the Low
value category.
Example 1: Adjust all of the ranges in vrbucket.ini
to:
[VCBValues]
High = 50
Moderate = 30
Some = 10
Example 2: To create two buckets (for example, High/Low
), change vrbucket.ini
to:
[VCBValues]
High = 25
Moderate = 25
Some = 25
The result of example 2 is:
High
is >25
Low
is >0 <25